Home Elevator OEM Sourcing & Specification Hub

Home Elevator OEM Sourcing & Specification Hub

Home Elevator OEM Sourcing & Specification Hub

Assemble a quotable specification in one pass. This hub pulls together the drive choice, modular structure, household power supply, car finish codes and order inputs behind a machine-room-less traction home elevator, and shows where a traction elevator layout stops fitting the building — so you can compare drive types, lock the configuration and brief your installer from a single reference.

Traction Home Elevator,kwinElevator,Machine Room Less Traction Home Elevator - Traction Elevator Manufacturer

Configuration snapshot

Four numbers that decide the quote

These are the figures buyers ask for first, and each one changes what your installer has to prepare on site.

220 V single phase Ordinary household electricity — no industrial power application required.
1.5 kW total Rated power during operation, including 1.1 kW for the drive system.
Machine room less The machine-room-less layout frees the shaft space a conventional machine room would take.
Knapsack or gantry Modular structure selected against the door opening demand of the house.

Step 2 — Structure

How the structure decides whether the shaft fits

Two decisions carry most of the space planning: which modular structure you take, and where the traction machine is mounted.

Traction home elevator structure and shaft arrangement for residential projects
  • Knapsack or gantry — picked from the door opening The structure is modular and can be adopted according to the door opening demand of the house structure. Start from where the door lands on each floor, then confirm the structure with the project team.
  • Machine-room-less layout frees usable space Eliminating the traditional machine room reduces construction complexity and cost while improving shaft space utilisation — the reason this design suits retrofits and space-constrained new villas.
  • The machine frame sits on the guide rail, not the building The special traction machine frame is fixed to the guide rail, so the building structure does not bear the force. That is what keeps an existing villa structurally straightforward.
  • Aluminium alloy frame keeps the weight down The frame is stated to weigh only one third of steel while carrying 20% more load-bearing capacity, and the modular build keeps the construction period short with minimal maintenance effort.

Step 3 — Specification

Configuration and specification matrix

Run down this table with your shaft drawing open. Every row is a line item you will be asked to confirm at quotation stage.

Traction Home Elevator — configuration reference
Drive and control
Drive technology VVVF drive for precise speed regulation and minimal operational noise
Control system Dedicated family-elevator microcomputer control board
Machine room Machine room less — no separate machine room required
Door machine Automatic special door machine with frequency conversion; energy-saving, safe and reliable
Structure and frame
Structure type Modular knapsack type or gantry type, adopted according to the door opening demand of the house structure
Frame material Aluminium alloy — lightweight and high-strength
Frame weight Stated as only one third of the weight of steel
Frame load-bearing Stated as 20% higher than steel
Machine mounting Special traction machine frame fixed to the guide rail, so the building does not bear the force
Power and backup
Power supply 220 V single phase household supply — no industrial power application needed
Rated power in operation 1.5 kW total, including 1.1 kW for the drive system
Consumption context Stated as less than the power of a microwave oven and about 80% less than a commercial elevator
Backup power UPS backup power supply for emergency evacuation during a power outage
Car interior (documented code KW-A-001)
Ceiling Mirror-finish stainless steel with acrylic light fixtures and recessed downlights
Sidewalls Mirror-finish stainless steel combined with anti-fingerprint stainless steel
Floor Stone panel or ceramic slab
Front wall Anti-fingerprint stainless steel
Door Anti-fingerprint stainless steel
Application
Typical projects Private homes, villas, mid-rise apartments and upscale residential buildings
Where it wins Retrofit projects, or new villas where space is constrained

Rated load, travel speed, number of stops and cabin dimensions are not published on the product page. Confirm them against your shaft drawing when you request a quote, so the quotation you receive matches the building rather than an assumed brochure figure.

Step 4 — Interior

Car interior and finish codes shown in the product gallery

The car interior is customizable, so the cabin is where an OEM order becomes a branded product. Work from these codes, then send the ones you want with your RFQ.

Step 5 — Order inputs

What to include in your OEM order

Five blocks of information turn an enquiry into a workable OEM or private-label order. Work through them once and you avoid the usual round of follow-up emails.

01 Shaft and space inputs

  • Shaft drawing with dimensions at each landing
  • Door opening position and width on every floor
  • Pit depth and overhead clearance available
  • Travel between the lowest and highest landing
  • Structural drawings for retrofit villas

02 Configuration choices

  • Production of the modules against the door opening demand of the house structure
  • Knapsack type or gantry type structure
  • Aluminium alloy frame specification
  • Machine-room-less layout confirmed with your installer
  • Traction machine frame mounted on the guide rail

03 Power and safety

  • Availability of a 220 V single-phase household supply
  • Circuit provision for the 1.5 kW rated load (1.1 kW drive system)
  • Position and specification of the UPS backup supply
  • Automatic frequency-conversion door machine requirements

04 Interior and branding

  • Decoration code for each car, for example KW-A-001
  • Ceiling, sidewall, floor, front wall and door materials
  • Private-label branding elements you want applied
  • Lighting arrangement in the ceiling

05 Commercial terms

  • Order quantity and repeat-order schedule
  • Packing requirement for sea freight
  • Shipping terms and destination port
  • Spare-parts list to keep on site
  • Documents you need to accompany the shipment

06 Before you send

  • One drawing set, one finish-code list, one RFQ
  • Flag any retrofit constraint on the first page
  • Note the power supply the site actually has
  • State your target installation window

Decision module

Match your building to the right configuration

Find the scenario closest to your project, read the product fact behind it, then take the decision it points to.

Scenario
Product fact
Decision you need to take
Retrofit into an existing villa with no spare room
The design is machine room less, so no dedicated machine room is built and shaft space utilisation improves.
Decide: where the shaft can be carved out and confirm the pit and overhead you actually have.
New villa where the door lands awkwardly
The modular structure can be adopted according to the door opening demand of the house structure — knapsack type or gantry type.
Decide: which structure matches your door position, then fix it before the shaft is built.
Site with household power only
220 V single phase, 1.5 kW total rated power including the 1.1 kW drive system — no industrial power supply application needed.
Decide: confirm the household circuit and where the UPS backup will sit.
Mid-rise apartment or upscale residential building
VVVF drive with a dedicated family-elevator microcomputer control board gives smooth running and low noise.
Decide: how many landings you are serving and how that changes the shaft and power run.
Dealer launching a private-label range
Car interiors are customizable, with decoration codes such as KW-A-001 combining mirror-finish and anti-fingerprint stainless steel, a stone or ceramic slab floor, and a stainless-steel door.
Decide: your finish codes, your branding elements and your packing requirement for sea freight.

Request a project quote

A traction home elevator quotation moves fastest when the shaft data, structure choice, power supply and finish codes arrive together. Send them in one message and the project team can come back with a configuration that fits your building rather than a generic figure.

  • → Shaft drawing and door opening positions
  • → Knapsack or gantry preference
  • → 220 V single-phase confirmation
  • → Car decoration codes
  • → Order quantity and destination port

Related Reading

Three notes to help clarify product requirements before contacting the supplier.

What Is a Machine Room Less Traction Home Elevator?

A machine room less traction home elevator is a fully enclosed passenger lift for a private low-rise house that carries people inside a compact shaft without a separate machine roo

Read article

What to Include in a Residential Elevator OEM Order to a Traction Elevator Supplier

A useful residential elevator OEM order reads like a compact project brief rather than a list of model names.

Read article

Low Energy Traction Villa Elevators for 220V Single-Phase Homes

A traction villa elevator can be connected to the same 220V single-phase household circuit that already supplies lighting and sockets when its drive electronics and mechanical syst

Read article

Frequently Asked Questions

does this traction home elevator need a separate machine room?

no. the design is machine room less. eliminating the traditional machine room reduces construction complexity and cost while improving shaft space utilisation, which is what makes the layout practical for retrofits and for new villas where space is constrained.

what power supply does it need?

a 220 v single-phase household supply. because it runs on ordinary household electricity, there is no need to apply for an industrial power supply. confirm the household circuit and the ups position with your installer before installation.

how much electricity does it use?

the total rated power during operation is 1.5 kw, including 1.1 kw for the drive system. the product page states this is less than the power of a microwave oven and around 80% less than a commercial elevator.

what happens during a power failure?

a ups backup power supply is part of the configuration, so the system can release passengers in the event of a power failure. plan where that backup unit will sit during the site survey.

should i choose the knapsack type or the gantry type structure?

both are modular and both can be adopted according to the door opening demand of the house structure. start from the door position and the shaft width available on each landing, then confirm the structure with the project team. the special traction machine frame is fixed to the guide rail either way, so the building does not bear the force.

can the car interior be customised to our own brand?

yes. the car interior is customisable, and the product gallery shows decoration codes such as kw-a-001, where the ceiling is mirror-finish stainless steel with acrylic light fixtures and recessed downlights, the sidewalls combine mirror-finish and anti-fingerprint stainless steel, the floor is a stone panel or ceramic slab, and the front wall and door are anti-fingerprint stainless steel. send your chosen codes with your rfq so the current component list can be confirmed.

Leave a message
First Name
Last Name
Email *
Message
whatsapp/phone
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.
Message Us