Standards ensure elevators are installed to prevent falls, entrapment, electrocution, and structural failure. Compliance is mandatory globally, with ISO 8100 and GB/T 7588 as the most widely applied frameworks. Would you like me to turn these requirements into a one-page installation checklist for on-site use?
Jun 1st,2026 39 Views

Elevator installation safety standards are a set of mandatory and recommended rules covering design, construction, electrical systems, safety components, and on-site acceptance. Below is a concise overview of global & Chinese core standards and key safety requirements for installation.

 

1. Major International Standards

  • ISO 8100 series(global baseline)
  • ISO 8100-1:2026: Safety rules for lifts (passenger/goods, traction/hydraulic)
  • ISO 8100-30:2019: Installation dimensions for Class I/II/III/VI lifts
    • EN 81 series(EU, widely adopted)
  • EN 81-1: Safety for construction & installation of passenger/goods lifts
    • ISO 22559-1:2014
  • Global Essential Safety Requirements (GESRs) for risk reduction

 

2. Core Chinese Standards (Mandatory + Recommended)

  • GB/T 7588.1-2020(primary, equivalent to EN 81-1)国家标准化管理委员会 
  • Safety rules for construction & installation of passenger/goods lifts国家标准化管理委员会
    • GB/T 10060-2023
  • Code for installation acceptance (≤6.0 m/s traction lifts)
    • GB/T 28621-2023
  • Safety for new lifts in existing buildings
    • T/CEA 0001-2020
  • China Elevator Association: Safety rules & essential technical requirements

 

3. Key Safety Requirements for Installation

3.1 Hoistway & Machine Room

  • Hoistway: Enclosed, fire-resistant; no unauthorized openings; adequate ventilation & lighting
  • Machine room: Min. height ≥2.0 m; secure access; main switch isolation; overload/overvoltage protection

3.2 Landing Doors & Car Doors

  • Landing door: Interlocked with car door; cannot open unless car is at floor; mechanical strength against impact
  • Car door: Safety edge (reverse on obstruction); door force ≤150 N; emergency release tool accessible

3.3 Car & Counterweight

  • Car: Enclosed; min. height ≥2.0 m; anti-fall guardrails on top; overload sensor (≥110% rated load = no start + alarm)
  • Counterweight: Securely fastened; minimum clearance from car/hoistway ≥50 mm

3.4 Safety Components (Critical)

  • Safety gear: Engages if overspeed/accidental movement; stops car on guide rails
  • Governor: Monitors speed; triggers safety gear at 115% rated speed
  • Buffer: At hoistway bottom; absorbs impact if car falls
  • Limit switches: Cut power at top/bottom travel limits

3.5 Electrical Safety

  • Earthing: All metal parts earthed; insulation resistance ≥0.5 MΩ
  • Fault protection: Phase loss/reversal protection; emergency stop button (red, prominent)
  • Emergency power: Lighting, intercom, and alarm work during power failure

3.6 Installation & Acceptance

  • Only licensed installers(manufacturer or authorized firms) permitted国家市场监督管理总局
  • Pre-use inspection: Safety gear, governor, buffers, door interlocks, and electrical systems tested
  • Documentation: Design files, quality certificate, installation manual, and inspection report required